A compact high resolution ion mobility spectrometer for fast trace gas analysis
Literature Information
Ansgar T. Kirk, Maria Allers, Philipp Cochems, Jens Langejuergen, Stefan Zimmermann
Drift tube ion mobility spectrometers (IMS) are widely used for fast trace gas detection in air, but portable compact systems are typically very limited in their resolving power. Decreasing the initial ion packet width improves the resolution, but is generally associated with a reduced signal-to-noise-ratio (SNR) due to the lower number of ions injected into the drift region. In this paper, we present a refined theory of IMS operation which employs a combined approach for the analysis of the ion drift and the subsequent amplification to predict both the resolution and the SNR of the measured ion current peak. This theoretical analysis shows that the SNR is not a function of the initial ion packet width, meaning that compact drift tube IMS with both very high resolution and extremely low limits of detection can be designed. Based on these implications, an optimized combination of a compact drift tube with a length of just 10 cm and a transimpedance amplifier has been constructed with a resolution of 183 measured for the positive reactant ion peak (RIP+), which is sufficient to e.g. separate the RIP+ from the protonated acetone monomer, even though their drift times only differ by a factor of 1.007. Furthermore, the limits of detection (LODs) for acetone are 180 pptv within 1 s of averaging time and 580 pptv within only 100 ms.
Recommended Journals
Related Literature
IF 4.616
Novel triazole-based fluorescent probes for Pd2+ in aqueous solutions: design, theoretical calculations and imagingIF 4.616
On-chip screening for prostate cancer: an EIS microfluidic platform for contemporary detection of free and total PSAIF 4.616
Environmentally friendly ionic liquid-in-water microemulsions for extraction of hydrophilic and lipophilic components from Flos ChrysanthemiIF 4.616
Electroanalytical methodologies for the detection of S-nitrosothiols in biological fluidsIF 4.616
Effects of surfactants on electrochemically prepared Ag nanostructuresIF 4.616
Photoelectrochemical lab-on-paper device based on molecularly imprinted polymer and porous Au-paper electrodeIF 4.616
Proteomics applied to the authentication of fish glue: application to a 17th century artwork sampleIF 4.616
Cholesterol determination using protein-templated fluorescent gold nanocluster probesIF 4.616
Design of a universal biointerface for sensitive, selective, and multiplex detection of biomarkers using surface plasmon resonance imagingIF 4.616
Source Journal
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.