Univariate calibration by reversed regression of heteroscedastic data: a case study
Literature Information
Joel Tellinghuisen
In a study of calibration with HPLC data for acetaldehyde-DNPH, we have collected replicate data (5–11 points each) for 33 samples spanning the range 0.0004–3 µg of detected analyte. Over most of this range, the data uncertainty is proportional to the signal, implying that weighted least squares is required to obtain the calibration function, since minimum-variance estimation requires weights inversely proportional to the data variance. When a variance function derived from an analysis of the replicate statistics is used to assign weights, wi = 1/σi2, the resulting values of χ2 for the calibration fit are too large by a factor of 400. This implies that the method error is dominated by sample preparation rather than measurement uncertainty, and it means that in the calibration fit, the peak area should be taken as the independent variable and the amount as the dependent. In this reversed regression, the generalized LS method (GLS) is used to estimate the total method variance function from the residuals. The resulting method variance function resembles the instrumental variance, in containing constant and proportional error terms. The calibration data demand at least a cubic polynomial for adequate representation, but other response functions are statistically equivalent, with the result that this model uncertainty is comparable to the directly computed statistical uncertainty of the calibration function. In these computations, emphasis is placed on the virtues of χ2 as a statistical figure of merit over the widely used R.
Related Literature
IF 6.367
Near infrared light activation of an injectable whole-cell cancer vaccine for cancer immunoprophylaxis and immunotherapyIF 6.843
Back coverIF 6.222
Surface structure-dependent electrocatalytic reduction of CO2 to C1 products on SnO2 catalystsIF 6.367
Highly efficient and durable III–V semiconductor-catalyst photocathodes via a transparent protection layerIF 6.367
From zinco(ii) arsaketenes to silylene-stabilised zinco arsinidene complexesIF 6.222
Enhanced activity of catalysts on substrates with surface protonic current in an electrical field – a reviewIF 6.222
Recent developments in carbon nitride based films for photoelectrochemical water splittingIF 6.367
Ether-functionalization of monoethanolamine (MEA) for reversible CO2 capture under solvent-free conditions with high-capacity and low-viscosityIF 6.367
An aminophosphonate ester ligand-containing platinum(ii) complex induces potent immunogenic cell death in vitro and elicits effective anti-tumour immune responses in vivoIF 6.222
Source Journal
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.