Univariate calibration by reversed regression of heteroscedastic data: a case study
文献情報
Joel Tellinghuisen
In a study of calibration with HPLC data for acetaldehyde-DNPH, we have collected replicate data (5–11 points each) for 33 samples spanning the range 0.0004–3 µg of detected analyte. Over most of this range, the data uncertainty is proportional to the signal, implying that weighted least squares is required to obtain the calibration function, since minimum-variance estimation requires weights inversely proportional to the data variance. When a variance function derived from an analysis of the replicate statistics is used to assign weights, wi = 1/σi2, the resulting values of χ2 for the calibration fit are too large by a factor of 400. This implies that the method error is dominated by sample preparation rather than measurement uncertainty, and it means that in the calibration fit, the peak area should be taken as the independent variable and the amount as the dependent. In this reversed regression, the generalized LS method (GLS) is used to estimate the total method variance function from the residuals. The resulting method variance function resembles the instrumental variance, in containing constant and proportional error terms. The calibration data demand at least a cubic polynomial for adequate representation, but other response functions are statistically equivalent, with the result that this model uncertainty is comparable to the directly computed statistical uncertainty of the calibration function. In these computations, emphasis is placed on the virtues of χ2 as a statistical figure of merit over the widely used R.
関連文献
IF 6.222
Transition metal chemistry in synthetically viable alkaline earth complexes M(Cp)3− (M = Ca, Sr, Ba)IF 6.222
Near infrared light activation of an injectable whole-cell cancer vaccine for cancer immunoprophylaxis and immunotherapyIF 6.843
Novel aqueous amine looping approach for the direct capture, conversion and storage of CO2 to produce magnesium carbonateIF 6.367
An environmentally friendly natural polymer as a universal interfacial modifier for fullerene and non-fullerene polymer solar cellsIF 6.367
Outstanding Reviewers for ChemComm in 2020IF 6.222
Microscopic insights into long-range 1D ordering in a dense semi-disordered molecular overlayerIF 6.222
Sugar ketals as a platform molecule to overcome the limitation of converting biomass into green-hydrocarbons in a typical refineryIF 6.367
Permselective ion electrosorption of subnanometer pores at high molar strength enables capacitive deionization of saline waterIF 6.367
Electrospun hydrogels for dynamic culture systems: advantages, progress, and opportunitiesIF 6.843
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.