Coupling liquid chromatography/mass spectrometry detection with microfluidic droplet array for label-free enzyme inhibition assay
Literature Information
Xiu-Li Wang, Ying Zhu
In this work, the combination of droplet-based microfluidics with liquid chromatography/mass spectrometry (LC/MS) was achieved, for providing a fast separation and high-information-content detection method for the analysis of nanoliter-scale droplets with complex compositions. A novel interface method was developed using an oil-covered droplet array chip to couple with an LC/MS system via a capillary sampling probe and a 4 nL injection valve without the need of a droplet extraction device. The present system can perform multistep operations including parallel enzyme inhibition reactions in nanoliter droplets, 4 nL sample injection, fast separation with capillary LC, and label-free detection with ESI-MS, and has significant flexibility in the accurate addressing and sampling of droplets of interest on demand. The system performance was evaluated using angiotensin I and angiotensin II as model samples, and the repeatabilities of peak area for angiotensin I and angiotensin II were 2.7% and 7.5% (RSD, n = 4), respectively. The present system was further applied to the screening for inhibitors of cytochrome P450 (CYP1A2) and measurement of the IC50 value of the inhibitor. The sample consumption for each droplet assay was 100 nL, which is reduced 10–100 times compared with conventional 384-multi-well plate systems usually used in high-throughput drug screening.
Related Literature
IF 4.616
Revisit of a dipropargyl rhodamine probe reveals its alternative ion sensitivity in both a solution and live cellsIF 4.616
Biomolecular dual-ion-trap mass analyzerIF 4.616
An X-ray transparent microfluidic platform for screening of the phase behavior of lipidic mesophasesIF 4.616
Coupling liquid chromatography/mass spectrometry detection with microfluidic droplet array for label-free enzyme inhibition assayIF 4.616
Selective detection of complementarity-determining regions of monoclonal antibody by limiting protease access to the substrate: nano-surface and molecular-orientation limited proteolysisIF 4.616
A simple and novel system for colorimetric detection of cobalt ionsIF 4.616
Quantification of plaque area and characterization of plaque biochemical composition with atherosclerosis progression in ApoE/LDLR−/− mice by FT-IR imagingIF 4.616
Direct comparison of fatty acid ratios in single cellular lipid droplets as determined by comparative Raman spectroscopy and gas chromatographyIF 4.616
Multi-functional fluorescent probe for Hg2+, Cu2+ and ClO− based on a pyrimidin-4-yl phenothiazine derivativeIF 4.616
Source Journal
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.