Retracted Article: Facile synthesis of quantum dots/mesoporous silica/quantum dots core/shell/shell hybrid microspheres for ratiometric fluorescence detection of 5-fluorouracil in human serum

Literature Information

Publication Date 2013-07-22
DOI 10.1039/C3AN01089A
Impact Factor 4.616
Authors

Rijun Gui, Ajun Wan, Hui Jin



Abstract

Compared to single photoluminescence (PL) intensity-based sensors, dual-emitting-based ratiometric PL sensors are more preferable because the influence from PL fluctuation in the reagents and background PL can be reduced to a minimum. However, so far no report has been directed to the ratiometric PL detection of 5-fluorouracil (5-FU). In this study, for the first time, high-quality quantum dots (QD1)/mesoporous silica (SiO2)/quantum dots (QD2) core/shell/shell hybrid microspheres (QD1/SiO2/QD2) were prepared by self-assembly, and further developed toward a ratiometric PL sensor of 5-FU. The addition of 5-FU induced regular PL quenching of QD2, but hardly influenced on the PL of QD1 in the microspheres. Based on the linear relationship (R = −0.9994) between the ratiometric PL intensity (IQD2/IQD1) and the molar concentration of 5-FU (0–1 μM), a ratiometric PL sensor for 5-FU was achieved and displays a low limit of detection (20 nM). Experimental results testified that this sensor for the detection of 5-FU in human serum samples was highly sensitive and selective over other inorganic ions and biological molecules. Compared with conventional analysis techniques and other spectrofluorimetric methods reported previously, this proposed ratiometric PL sensor could be a good candidate for the highly efficient detection of 5-FU.

Source Journal

Analyst

Analyst
CiteScore: 7.8
Self-citation Rate: 5.6%
Articles per Year: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

Recommended Suppliers

ChinaWuxi Guangshun Petrochemical Instrument Factory
GermanyKemira Germany GmbH
ChinaNantong Xiao Chang Medical Trade Co., Ltd.
GermanyHelga B. Koch und Günter Koch GbR
ChinaShaanxi Shengan Industry Co., Ltd.
DataApex
AustriaAGRU Kunststofftechnik GmbH
AustriaZeller GmbH
ChinaShenyang Remote Chemical Plant
GermanyAGROMATIC Regelungstechnik GmbH
Disclaimer
This page provides academic journal information for reference and research purposes only. We are not affiliated with any journal publishers and do not handle publication submissions. For publication-related inquiries, please contact the respective journal publishers directly.
If you notice any inaccuracies in the information displayed, please contact us at [email protected]. We will promptly review and address your concerns.