Automated molecular formula determination by tandem mass spectrometry (MS/MS)
文献信息
Christophe Deprez, Taira Kiyota, Cristina Draghici, Enrico Purisima, Yasuo Konishi
Automated software was developed to analyze the molecular formula of organic molecules and peptides based on high-resolution MS/MS spectroscopic data. The software was validated with 96 compounds including a few small peptides in the mass range of 138–1569 Da containing the elements carbon, hydrogen, nitrogen and oxygen. A Micromass Waters Q-TOF Ultima Global mass spectrometer was used to measure the molecular masses of precursor and fragment ions. Our software assigned correct molecular formulas for 91 compounds, incorrect molecular formulas for 3 compounds, and no molecular formula for 2 compounds. The obtained 95% success rate indicates high reliability of the software. The mass accuracy of the precursor ion and the fragment ions, which is critical for the success of the analysis, was high, i.e. the accuracy and the precision of 850 data were 0.0012 Da and 0.0016 Da, respectively. For the precursor and fragment ions below 500 Da, 60% and 90% of the data showed accuracy within ≤0.001 Da and ≤0.002 Da, respectively. The precursor and fragment ions above 500 Da showed slightly lower accuracy, i.e. 40% and 70% of them showed accuracy within ≤0.001 Da and ≤0.002 Da, respectively. The molecular formulas of the precursor and the fragments were further used to analyze possible mass spectrometric fragmentation pathways, which would be a powerful tool in structural analysis and identification of small molecules. The method is valuable in the rapid screening and identification of small molecules such as the dereplication of natural products, characterization of drug metabolites, and identification of small peptide fragments in proteomics. The analysis was also extended to compounds that contain a chlorine or bromine atom.
相关文献
IF 6.843
Synthesis and optical and electronic properties of one-dimensional sulfoxonium-based hybrid metal halide (CH3)3SOPbI3IF 6.222
Performance of electrode-supported silica membrane separators in lithium-ion batteriesIF 6.367
Coexisting order and disorder within a common 40-residue amyloid-β fibril structure in Alzheimer's disease brain tissueIF 6.222
Permselective ion electrosorption of subnanometer pores at high molar strength enables capacitive deionization of saline waterIF 6.367
Near infrared light activation of an injectable whole-cell cancer vaccine for cancer immunoprophylaxis and immunotherapyIF 6.843
Three-terminal III–V/Si tandem solar cells enabled by a transparent conductive adhesiveIF 6.367
Developing a novel high performance NaNbO3-based lead-free dielectric capacitor for energy storage applicationsIF 6.367
Solventless thermal crosslinked polymer protective layer for high stable lithium metal batteriesIF 6.367
Pulsed laser rusted stainless steel: a robust electrode material applied for energy storage and generation applicationsIF 6.367
来源期刊
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.